The connection of the quartz sand pipeline adopts the socket-type sealing connection method, which is fast, accurate, time-saving, and labor-saving. In special circumstances, flange connection or other forms of connection can also be used. The FRP pipeline connection consists of two parts: a special rubber inner lining and a glass fiber reinforced polyvinyl acetate outer wall. The FRP pipeline adopts full surface thermosetting cross-linking technology, which has reliable mechanical performance, corrosion resistance, and sealing performance. In general, the socket-type sealing connection can ensure fast, accurate, time-saving, and labor-saving connection. Additionally, flange connection or other methods can also be utilized.Fiberglass cable conduit is a category of TOPTION FRP piping products, which uses resin as the matrix and continuous FRP and its fabric as the reinforcing material. It is a type of conduit formed using computer-controlled winding or extrusion processes.1) High strength, used for straightening under the roadway without a protective layer, which can accelerate the construction progress. 2) Good toughness, able to resist external pressure and damage caused by foundation settlement. 3) Good electrical insulation, flame retardant, and heat-resistant properties, can be used long-term at a high temperature of 130 degrees without deformation. 4) Corrosion-resistant, with long service life, able to resist corrosion from various corrosive media such as acid, alkali, salt, and organic solvents, and its service life can reach 50 years. 5) Smooth inner wall, does not scratch cables. Rubber-sealed joints are convenient for installation and connection, and can adapt to thermal expansion and contraction. 6) Small specific gravity, light weight, can be lifted by one person and installed by two people, greatly reducing the construction period and installation costs. At the same time, FRP cable conduit avoids the problem of long exposure time caused by road excavation, affecting urban traffic order, etc. 7) No electric corrosion, non-magnetic. Unlike magnetic materials such as steel pipes, it will not cause cable heating damage due to eddy currents. 8) Wide application range, FRP cable conduits are used as protective tubes for buried cables, as well as in high-demand scenarios such as cable bridges and crossings. The use of matching professional pipe pillows can form a multi-layer and multi-column multi-conduit arrangementFRP Sand Pipe Parameter Form(*Note: Our product’s length is 12 meters)
nominal stiffness 2500Pa stiffness 3750Pa stiffness 5000Pa stiffness 7500Pa stiffness  
  0.25 MPa 0.6 MPa 1.0 MPa 0.25 MPa 0.6 MPa 1.0 MPa 0.25 MPa 0.6 MPa 1.0 MPa 1.6 MPa 0.25 MPa 0.6 MPa 1.0 MPa 1.6 MPa 1.0 MPa 1.6 MPa
300 5.00 5.00 5.00 5.00 5.00 5.00 5.40 5.30 5.30   6.10 6.10 6.00 5.80 6.50 6.30
400 5.70 5.70 5.50 6.30 6.30 6.30 6.80 6.80 6.60   8.00 8.00 7.50 7.40 8.30 8.10
500 6.90 6.70 6.60 7.70 7.70 7.50 8.50 8.40 8.00   9.70 9.50 9.10 8.80 10.10 9.80
600 8.20 7.70 7.70 9.20 9.10 8.50 10.20 9.70 9.30   11.50 11.40 10.70 10.50 11.70 11.50
700 9.50 8.80 8.60 10.80 10.30 10.00 12.00 11.30 10.70   13.60 13.00 12.40 11.90 13.50 13.10
800 10.90 10.20 9.90 12.40 11.50 11.00 13.70 13.20 12.10   15.80 14.70 14.00 13.50 15.20 14.80
900 12.20 11.40 10.80 14.00 12.90 12.30 15.50 14.40 13.50   17.90 16.90 15.60 15.10 17.10 16.60
1000 13.50 12.40 11.90 15.60 14.20 13.50 17.30 16.00 14.90   20.00 18.50 17.30 16.50 18.80 18.20
1200 16.00 14.70 14.00 18.50 16.80 16.20 21.00 19.10 17.80   23.70 22.00 20.30 19.70 22.40 21.60
1400 18.20 17.00 16.00 21.50 19.60 18.50 24.00 22.00 20.30   27.40 25.40 23.40 22.60 26.40 25.20
1600 21.30 19.20 18.30 24.10 22.20 21.00 27.60 24.80 23.00 22.40 31.30 29.00 26.60 25.80 29.80 28.40
1800 23.30 21.50 20.50 27.20 25.00 23.50 30.80 27.60 25.80 25.20 35.00 32.40 29.90 29.00 33.10 31.40
2000 25.90 24.00 22.50 30.00 27.50 16.00 34.00 30.50 28.50 27.70 38.70 36.00 33.00 31.80 36.60 34.80
2200 28.50 26.10 24.70 32.80 30.00 28.50 37.00 33.50 31.20 30.40 43.00 39.30 36.20 35.00 40.20 38.10
2400 31.10 28.40 26.80 36.00 32.80 30.90 40.30 36.40 34.00 33.20 46.20 42.80 39.20 35.00 44.00 41.50
2600 34.00 30.70 29.00 39.00 35.20 33.40 44.00 39.40 36.50 35.80 50.40 48.00 42.40 41.20 47.50 45.50
1.The fiberglass reinforced plastic (FRP) process pipes have high resistance to corrosion as different types of anti-corrosion resins can be selected for lining, suitable for various types of acids, alkalis, salts, oils, seawater, and organic solvents. 2.The operating temperature of FRP process pipes is below 150℃, making it suitable for use in different types of soils. It is applicable for conveying drinking water, sewage, seawater, circulating water pipelines in power plants, conveying corrosive media in chemical enterprises, oil and gas transportation, agricultural irrigation, etc. 3.The FRP process pipes are lightweight, easy to maintain, and highly durable. 4.The installation of FRP pipes is easy as there are no technical limitations on the length of the pipes. However, due to transportation considerations, the length is generally within 12m to reduce the number of joints. The lightweight of FRP pipelines also enables manual or light installation equipment to be used for convenient and quick installation. 5.The FRP pipelines have strong adaptability as they are available in standard sizes ranging from 50mm to 4200mm. The long-term pressure resistance of the pipeline is generally within 1.6Mpa, but can reach up to 6.4Mpa or more depending on the user's special requirements. 6.The FRP process pipes have higher transport efficiency as the inner wall of the pipeline is smooth, with a roughness coefficient N≤0.0084. Compared with traditional materials of the same diameter, the FRP pipes have higher hydraulic capacity, which saves pump energy and prolongs the life of the project and equipment. 7.The FRP process pipes have low permeation rate due to their good sealing connection and longer pipe length when compared with traditional materials.(*Note: The specifications of the pipe is the minimum wall thickness of the ventilation pipe. Other requirements can be specified by the customer)  
DN(mm) 50 65 80 100 125 150 175 200 280 300 350 400 450
Standard thickness T(mm) 3 3 3 3 3.5 3.5 3.5 3.5 4 4 4 4 4.5
Standard length L(mm) 6 6 6 6 6 6 6 6 12 12 12 12 12
 
DN(mm) 500 550 600 700 800 900 1000 1200 1400 1500 1600 1800 2000
Standard thickness T(mm) 4.5 4.5 5 6 6 7 8 8 9 10 10 11 12
Standard length L(mm) 12 12 12 12 12 12 12 12 12 12 12 12 12
 
DN(mm) 2200 2400 2500 2600 2800 3000 3200 3400 3500 3800 4000 4200  
Standard thickness T(mm) thickness is determined by design
Standard length L(mm) 12 12 12 12 12 12 12 12 12 12 12 12
Fiberglass cable conduits are suitable for protecting cables in various environments, including power and communication cables. They are especially useful in special environments such as crossing traffic thoroughfares, rivers and bridges, where their construction is simple, and their high strength and other excellent characteristics can be fully utilized. They are widely used in the infrastructure construction fields of power, communication, transportation, and civil aviation airports.
Type Specification D T D1 D2 D3 T S S1 Z L weight kg/m
BBB-50/5 50 5 60 68 78 5 110 80 83 4000 1.8
BBB-70/5 70 5 80 88 98 5 110 80 83 4000 2.3
BBB-80/5 80 5 90 98 108 5 110 80 83 4000 2.7
BBB-100/5 100 5 110 118 125 5 130 80 83 4000 3.3
BBB-100/8 100 8 116 124 140 8 130 80 83 4000 5.4
BBB-125/5 125 5 135 143 153 5 130 100 105 4000 3.8
BBB-150/3 150 0 156 164 170 3 160 100 105 4000 2.8
BBB-150/5 150 5 160 168 178 5 160 100 105 4000 4.8
BBB-150/8 150 8 166 175 190 8 160 100 105 4000 758
BBB-150/10 150 10 170 178 198 10 160 100 105 4000 9.5
BBB-175/10 175 10 195 203 223 10 160 100 105 4000 11.0
BBB-200/10 200 10 220 228 248 10 180 120 125 4000 12.4
BBB-200/12 200 12 224 232 257 12 180 120 125 4000 15.0

Hot Products

Walnut Shell Filter for Water Treatment

Walnut Shell Filter for Water Treatment

EDI Water Equipment Introduction

EDI Water Equipment Introduction

Fiber Ball Filter

Fiber Ball Filter

Wastewater Treatment Integration Equipment

Wastewater Treatment Integration Equipment

RO water equipment / Reverse Osmosis equipment

RO water equipment / Reverse Osmosis equipment

Inclined Tube Sedimentation Tank

Inclined Tube Sedimentation Tank

Seawater Desalination Equipment

Seawater Desalination Equipment

Laminated Filter

Laminated Filter

Fiberglass Reinforced Plastic/ FRP Fittings Series

Fiberglass Reinforced Plastic/ FRP Fittings Series

Single Stage Water Softening Equipment

Single Stage Water Softening Equipment

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours